   1* ST-Ericsson DB8500 Thermal
   2
   3** Thermal node properties:
   4
   5- compatible : "stericsson,db8500-thermal";
   6- reg : address range of the thermal sensor registers;
   7- interrupts : interrupts generated from PRCMU;
   8- interrupt-names : "IRQ_HOTMON_LOW" and "IRQ_HOTMON_HIGH";
   9- num-trips : number of total trip points, this is required, set it 0 if none,
  10  if greater than 0, the following properties must be defined;
  11- tripN-temp : temperature of trip point N, should be in ascending order;
  12- tripN-type : type of trip point N, should be one of "active" "passive" "hot"
  13  "critical";
  14- tripN-cdev-num : number of the cooling devices which can be bound to trip
  15  point N, this is required if trip point N is defined, set it 0 if none,
  16  otherwise the following cooling device names must be defined;
  17- tripN-cdev-nameM : name of the No. M cooling device of trip point N;
  18
  19Usually the num-trips and tripN-*** are separated in board related dts files.
  20
  21Example:
  22thermal@801573c0 {
  23        compatible = "stericsson,db8500-thermal";
  24        reg = <0x801573c0 0x40>;
  25        interrupts = <21 0x4>, <22 0x4>;
  26        interrupt-names = "IRQ_HOTMON_LOW", "IRQ_HOTMON_HIGH";
  27
  28        num-trips = <3>;
  29
  30        trip0-temp = <75000>;
  31        trip0-type = "active";
  32        trip0-cdev-num = <1>;
  33        trip0-cdev-name0 = "thermal-cpufreq-0";
  34
  35        trip1-temp = <80000>;
  36        trip1-type = "active";
  37        trip1-cdev-num = <2>;
  38        trip1-cdev-name0 = "thermal-cpufreq-0";
  39        trip1-cdev-name1 = "thermal-fan";
  40
  41        trip2-temp = <85000>;
  42        trip2-type = "critical";