   2# Generic thermal sysfs drivers configuration
   3#
   4
   5menuconfig THERMAL
   6        tristate "Generic Thermal sysfs driver"
   7        help
   8          Generic Thermal Sysfs driver offers a generic mechanism for
   9          thermal management. Usually it's made up of one or more thermal
  10          zone and cooling device.
  11          Each thermal zone contains its own temperature, trip points,
  12          cooling devices.
  13          All platforms with ACPI thermal support can use this driver.
  14          If you want this support, you should say Y or M here.
  15
  16if THERMAL
  17
  18config THERMAL_HWMON
  19        bool
  20        depends on HWMON=y || HWMON=THERMAL
  21        default y
  22
  23choice
  24        prompt "Default Thermal governor"
  25        default THERMAL_DEFAULT_GOV_STEP_WISE
  26        help
  27          This option sets which thermal governor shall be loaded at
  28          startup. If in doubt, select 'step_wise'.
  29
  30config THERMAL_DEFAULT_GOV_STEP_WISE
  31        bool "step_wise"
  32        select STEP_WISE
  33        help
  34          Use the step_wise governor as default. This throttles the
  35          devices one step at a time.
  36
  37config THERMAL_DEFAULT_GOV_FAIR_SHARE
  38        bool "fair_share"
  39        select FAIR_SHARE
  40        help
  41          Use the fair_share governor as default. This throttles the
  42          devices based on their 'contribution' to a zone. The
  43          contribution should be provided through platform data.
  44
  45config THERMAL_DEFAULT_GOV_USER_SPACE
  46        bool "user_space"
  47        select USER_SPACE
  48        help
  49          Select this if you want to let the user space manage the
  50          lpatform thermals.
  51
  52endchoice
  53
  54config FAIR_SHARE
  55        bool "Fair-share thermal governor"
  56        help
  57          Enable this to manage platform thermals using fair-share governor.
  58
  59config STEP_WISE
  60        bool "Step_wise thermal governor"
  61        help
  62          Enable this to manage platform thermals using a simple linear
  63
  64config USER_SPACE
  65        bool "User_space thermal governor"
  66        help
  67          Enable this to let the user space manage the platform thermals.
  68
  69config CPU_THERMAL
  70        tristate "generic cpu cooling support"
  71        depends on CPU_FREQ
  72        select CPU_FREQ_TABLE
  73        help
  74          This implements the generic cpu cooling mechanism through frequency
  75          reduction, cpu hotplug and any other ways of reducing temperature. An
  76          ACPI version of this already exists(drivers/acpi/processor_thermal.c).
  77          This will be useful for platforms using the generic thermal interface
  78          and not the ACPI interface.
  79          If you want this support, you should say Y here.
  80
  81config SPEAR_THERMAL
  82        bool "SPEAr thermal sensor driver"
  83        depends on PLAT_SPEAR
  84        depends on OF
  85        help
  86          Enable this to plug the SPEAr thermal sensor driver into the Linux
  87          thermal framework
  88
  89config RCAR_THERMAL
  90        tristate "Renesas R-Car thermal driver"
  91        depends on ARCH_SHMOBILE
  92        help
  93          Enable this to plug the R-Car thermal sensor driver into the Linux
  94          thermal framework
  95
  96config EXYNOS_THERMAL
  97        tristate "Temperature sensor on Samsung EXYNOS"
  98        depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
  99        depends on CPU_THERMAL
 100        help
 101          If you say yes here you get support for TMU (Thermal Management
 102          Unit) on SAMSUNG EXYNOS series of SoC.
 103
 104config DB8500_THERMAL
 105        bool "DB8500 thermal management"
 106        depends on ARCH_U8500
 107        default y
 108        help
 109          Adds DB8500 thermal management implementation according to the thermal
 110          management framework. A thermal zone with several trip points will be
 111          created. Cooling devices can be bound to the trip points to cool this
 112          thermal zone if trip points reached.
 113
 114config DB8500_CPUFREQ_COOLING
 115        tristate "DB8500 cpufreq cooling"
 116        depends on ARCH_U8500
 117        depends on CPU_THERMAL
 118        default y
 119        help
 120          Adds DB8500 cpufreq cooling devices, and these cooling devices can be
 121          bound to thermal zone trip points. When a trip point reached, the
 122          bound cpufreq cooling device turns active to set CPU frequency low to
 123          cool down the CPU.