linux/Documentation/blockdev/README.DAC960
<<
>>
Prefs
   1   Linux Driver for Mylex DAC960/AcceleRAID/eXtremeRAID PCI RAID Controllers
   2
   3                        Version 2.2.11 for Linux 2.2.19
   4                        Version 2.4.11 for Linux 2.4.12
   5
   6                              PRODUCTION RELEASE
   7
   8                                11 October 2001
   9
  10                               Leonard N. Zubkoff
  11                               Dandelion Digital
  12                               lnz@dandelion.com
  13
  14         Copyright 1998-2001 by Leonard N. Zubkoff <lnz@dandelion.com>
  15
  16
  17                                 INTRODUCTION
  18
  19Mylex, Inc. designs and manufactures a variety of high performance PCI RAID
  20controllers.  Mylex Corporation is located at 34551 Ardenwood Blvd., Fremont,
  21California 94555, USA and can be reached at 510.796.6100 or on the World Wide
  22Web at http://www.mylex.com.  Mylex Technical Support can be reached by
  23electronic mail at mylexsup@us.ibm.com, by voice at 510.608.2400, or by FAX at
  24510.745.7715.  Contact information for offices in Europe and Japan is available
  25on their Web site.
  26
  27The latest information on Linux support for DAC960 PCI RAID Controllers, as
  28well as the most recent release of this driver, will always be available from
  29my Linux Home Page at URL "http://www.dandelion.com/Linux/".  The Linux DAC960
  30driver supports all current Mylex PCI RAID controllers including the new
  31eXtremeRAID 2000/3000 and AcceleRAID 352/170/160 models which have an entirely
  32new firmware interface from the older eXtremeRAID 1100, AcceleRAID 150/200/250,
  33and DAC960PJ/PG/PU/PD/PL.  See below for a complete controller list as well as
  34minimum firmware version requirements.  For simplicity, in most places this
  35documentation refers to DAC960 generically rather than explicitly listing all
  36the supported models.
  37
  38Driver bug reports should be sent via electronic mail to "lnz@dandelion.com".
  39Please include with the bug report the complete configuration messages reported
  40by the driver at startup, along with any subsequent system messages relevant to
  41the controller's operation, and a detailed description of your system's
  42hardware configuration.  Driver bugs are actually quite rare; if you encounter
  43problems with disks being marked offline, for example, please contact Mylex
  44Technical Support as the problem is related to the hardware configuration
  45rather than the Linux driver.
  46
  47Please consult the RAID controller documentation for detailed information
  48regarding installation and configuration of the controllers.  This document
  49primarily provides information specific to the Linux support.
  50
  51
  52                                DRIVER FEATURES
  53
  54The DAC960 RAID controllers are supported solely as high performance RAID
  55controllers, not as interfaces to arbitrary SCSI devices.  The Linux DAC960
  56driver operates at the block device level, the same level as the SCSI and IDE
  57drivers.  Unlike other RAID controllers currently supported on Linux, the
  58DAC960 driver is not dependent on the SCSI subsystem, and hence avoids all the
  59complexity and unnecessary code that would be associated with an implementation
  60as a SCSI driver.  The DAC960 driver is designed for as high a performance as
  61possible with no compromises or extra code for compatibility with lower
  62performance devices.  The DAC960 driver includes extensive error logging and
  63online configuration management capabilities.  Except for initial configuration
  64of the controller and adding new disk drives, most everything can be handled
  65from Linux while the system is operational.
  66
  67The DAC960 driver is architected to support up to 8 controllers per system.
  68Each DAC960 parallel SCSI controller can support up to 15 disk drives per
  69channel, for a maximum of 60 drives on a four channel controller; the fibre
  70channel eXtremeRAID 3000 controller supports up to 125 disk drives per loop for
  71a total of 250 drives.  The drives installed on a controller are divided into
  72one or more "Drive Groups", and then each Drive Group is subdivided further
  73into 1 to 32 "Logical Drives".  Each Logical Drive has a specific RAID Level
  74and caching policy associated with it, and it appears to Linux as a single
  75block device.  Logical Drives are further subdivided into up to 7 partitions
  76through the normal Linux and PC disk partitioning schemes.  Logical Drives are
  77also known as "System Drives", and Drive Groups are also called "Packs".  Both
  78terms are in use in the Mylex documentation; I have chosen to standardize on
  79the more generic "Logical Drive" and "Drive Group".
  80
  81DAC960 RAID disk devices are named in the style of the obsolete Device File
  82System (DEVFS).  The device corresponding to Logical Drive D on Controller C
  83is referred to as /dev/rd/cCdD, and the partitions are called /dev/rd/cCdDp1
  84through /dev/rd/cCdDp7.  For example, partition 3 of Logical Drive 5 on
  85Controller 2 is referred to as /dev/rd/c2d5p3.  Note that unlike with SCSI
  86disks the device names will not change in the event of a disk drive failure.
  87The DAC960 driver is assigned major numbers 48 - 55 with one major number per
  88controller.  The 8 bits of minor number are divided into 5 bits for the Logical
  89Drive and 3 bits for the partition.
  90
  91
  92          SUPPORTED DAC960/AcceleRAID/eXtremeRAID PCI RAID CONTROLLERS
  93
  94The following list comprises the supported DAC960, AcceleRAID, and eXtremeRAID
  95PCI RAID Controllers as of the date of this document.  It is recommended that
  96anyone purchasing a Mylex PCI RAID Controller not in the following table
  97contact the author beforehand to verify that it is or will be supported.
  98
  99eXtremeRAID 3000
 100            1 Wide Ultra-2/LVD SCSI channel
 101            2 External Fibre FC-AL channels
 102            233MHz StrongARM SA 110 Processor
 103            64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
 104            32MB/64MB ECC SDRAM Memory
 105
 106eXtremeRAID 2000
 107            4 Wide Ultra-160 LVD SCSI channels
 108            233MHz StrongARM SA 110 Processor
 109            64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
 110            32MB/64MB ECC SDRAM Memory
 111
 112AcceleRAID 352
 113            2 Wide Ultra-160 LVD SCSI channels
 114            100MHz Intel i960RN RISC Processor
 115            64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
 116            32MB/64MB ECC SDRAM Memory
 117
 118AcceleRAID 170
 119            1 Wide Ultra-160 LVD SCSI channel
 120            100MHz Intel i960RM RISC Processor
 121            16MB/32MB/64MB ECC SDRAM Memory
 122
 123AcceleRAID 160 (AcceleRAID 170LP)
 124            1 Wide Ultra-160 LVD SCSI channel
 125            100MHz Intel i960RS RISC Processor
 126            Built in 16M ECC SDRAM Memory
 127            PCI Low Profile Form Factor - fit for 2U height
 128
 129eXtremeRAID 1100 (DAC1164P)
 130            3 Wide Ultra-2/LVD SCSI channels
 131            233MHz StrongARM SA 110 Processor
 132            64 Bit 33MHz PCI (backward compatible with 32 Bit PCI slots)
 133            16MB/32MB/64MB Parity SDRAM Memory with Battery Backup
 134
 135AcceleRAID 250 (DAC960PTL1)
 136            Uses onboard Symbios SCSI chips on certain motherboards
 137            Also includes one onboard Wide Ultra-2/LVD SCSI Channel
 138            66MHz Intel i960RD RISC Processor
 139            4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
 140
 141AcceleRAID 200 (DAC960PTL0)
 142            Uses onboard Symbios SCSI chips on certain motherboards
 143            Includes no onboard SCSI Channels
 144            66MHz Intel i960RD RISC Processor
 145            4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
 146
 147AcceleRAID 150 (DAC960PRL)
 148            Uses onboard Symbios SCSI chips on certain motherboards
 149            Also includes one onboard Wide Ultra-2/LVD SCSI Channel
 150            33MHz Intel i960RP RISC Processor
 151            4MB Parity EDO Memory
 152
 153DAC960PJ    1/2/3 Wide Ultra SCSI-3 Channels
 154            66MHz Intel i960RD RISC Processor
 155            4MB/8MB/16MB/32MB/64MB/128MB ECC EDO Memory
 156
 157DAC960PG    1/2/3 Wide Ultra SCSI-3 Channels
 158            33MHz Intel i960RP RISC Processor
 159            4MB/8MB ECC EDO Memory
 160
 161DAC960PU    1/2/3 Wide Ultra SCSI-3 Channels
 162            Intel i960CF RISC Processor
 163            4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory
 164
 165DAC960PD    1/2/3 Wide Fast SCSI-2 Channels
 166            Intel i960CF RISC Processor
 167            4MB/8MB EDRAM or 2MB/4MB/8MB/16MB/32MB DRAM Memory
 168
 169DAC960PL    1/2/3 Wide Fast SCSI-2 Channels
 170            Intel i960 RISC Processor
 171            2MB/4MB/8MB/16MB/32MB DRAM Memory
 172
 173DAC960P     1/2/3 Wide Fast SCSI-2 Channels
 174            Intel i960 RISC Processor
 175            2MB/4MB/8MB/16MB/32MB DRAM Memory
 176
 177For the eXtremeRAID 2000/3000 and AcceleRAID 352/170/160, firmware version
 1786.00-01 or above is required.
 179
 180For the eXtremeRAID 1100, firmware version 5.06-0-52 or above is required.
 181
 182For the AcceleRAID 250, 200, and 150, firmware version 4.06-0-57 or above is
 183required.
 184
 185For the DAC960PJ and DAC960PG, firmware version 4.06-0-00 or above is required.
 186
 187For the DAC960PU, DAC960PD, DAC960PL, and DAC960P, either firmware version
 1883.51-0-04 or above is required (for dual Flash ROM controllers), or firmware
 189version 2.73-0-00 or above is required (for single Flash ROM controllers)
 190
 191Please note that not all SCSI disk drives are suitable for use with DAC960
 192controllers, and only particular firmware versions of any given model may
 193actually function correctly.  Similarly, not all motherboards have a BIOS that
 194properly initializes the AcceleRAID 250, AcceleRAID 200, AcceleRAID 150,
 195DAC960PJ, and DAC960PG because the Intel i960RD/RP is a multi-function device.
 196If in doubt, contact Mylex RAID Technical Support (mylexsup@us.ibm.com) to
 197verify compatibility.  Mylex makes available a hard disk compatibility list at
 198http://www.mylex.com/support/hdcomp/hd-lists.html.
 199
 200
 201                              DRIVER INSTALLATION
 202
 203This distribution was prepared for Linux kernel version 2.2.19 or 2.4.12.
 204
 205To install the DAC960 RAID driver, you may use the following commands,
 206replacing "/usr/src" with wherever you keep your Linux kernel source tree:
 207
 208  cd /usr/src
 209  tar -xvzf DAC960-2.2.11.tar.gz (or DAC960-2.4.11.tar.gz)
 210  mv README.DAC960 linux/Documentation
 211  mv DAC960.[ch] linux/drivers/block
 212  patch -p0 < DAC960.patch (if DAC960.patch is included)
 213  cd linux
 214  make config
 215  make bzImage (or zImage)
 216
 217Then install "arch/x86/boot/bzImage" or "arch/x86/boot/zImage" as your
 218standard kernel, run lilo if appropriate, and reboot.
 219
 220To create the necessary devices in /dev, the "make_rd" script included in
 221"DAC960-Utilities.tar.gz" from http://www.dandelion.com/Linux/ may be used.
 222LILO 21 and FDISK v2.9 include DAC960 support; also included in this archive
 223are patches to LILO 20 and FDISK v2.8 that add DAC960 support, along with
 224statically linked executables of LILO and FDISK.  This modified version of LILO
 225will allow booting from a DAC960 controller and/or mounting the root file
 226system from a DAC960.
 227
 228Red Hat Linux 6.0 and SuSE Linux 6.1 include support for Mylex PCI RAID
 229controllers.  Installing directly onto a DAC960 may be problematic from other
 230Linux distributions until their installation utilities are updated.
 231
 232
 233                              INSTALLATION NOTES
 234
 235Before installing Linux or adding DAC960 logical drives to an existing Linux
 236system, the controller must first be configured to provide one or more logical
 237drives using the BIOS Configuration Utility or DACCF.  Please note that since
 238there are only at most 6 usable partitions on each logical drive, systems
 239requiring more partitions should subdivide a drive group into multiple logical
 240drives, each of which can have up to 6 usable partitions.  Also, note that with
 241large disk arrays it is advisable to enable the 8GB BIOS Geometry (255/63)
 242rather than accepting the default 2GB BIOS Geometry (128/32); failing to so do
 243will cause the logical drive geometry to have more than 65535 cylinders which
 244will make it impossible for FDISK to be used properly.  The 8GB BIOS Geometry
 245can be enabled by configuring the DAC960 BIOS, which is accessible via Alt-M
 246during the BIOS initialization sequence.
 247
 248For maximum performance and the most efficient E2FSCK performance, it is
 249recommended that EXT2 file systems be built with a 4KB block size and 16 block
 250stride to match the DAC960 controller's 64KB default stripe size.  The command
 251"mke2fs -b 4096 -R stride=16 <device>" is appropriate.  Unless there will be a
 252large number of small files on the file systems, it is also beneficial to add
 253the "-i 16384" option to increase the bytes per inode parameter thereby
 254reducing the file system metadata.  Finally, on systems that will only be run
 255with Linux 2.2 or later kernels it is beneficial to enable sparse superblocks
 256with the "-s 1" option.
 257
 258
 259                      DAC960 ANNOUNCEMENTS MAILING LIST
 260
 261The DAC960 Announcements Mailing List provides a forum for informing Linux
 262users of new driver releases and other announcements regarding Linux support
 263for DAC960 PCI RAID Controllers.  To join the mailing list, send a message to
 264"dac960-announce-request@dandelion.com" with the line "subscribe" in the
 265message body.
 266
 267
 268                CONTROLLER CONFIGURATION AND STATUS MONITORING
 269
 270The DAC960 RAID controllers running firmware 4.06 or above include a Background
 271Initialization facility so that system downtime is minimized both for initial
 272installation and subsequent configuration of additional storage.  The BIOS
 273Configuration Utility (accessible via Alt-R during the BIOS initialization
 274sequence) is used to quickly configure the controller, and then the logical
 275drives that have been created are available for immediate use even while they
 276are still being initialized by the controller.  The primary need for online
 277configuration and status monitoring is then to avoid system downtime when disk
 278drives fail and must be replaced.  Mylex's online monitoring and configuration
 279utilities are being ported to Linux and will become available at some point in
 280the future.  Note that with a SAF-TE (SCSI Accessed Fault-Tolerant Enclosure)
 281enclosure, the controller is able to rebuild failed drives automatically as
 282soon as a drive replacement is made available.
 283
 284The primary interfaces for controller configuration and status monitoring are
 285special files created in the /proc/rd/... hierarchy along with the normal
 286system console logging mechanism.  Whenever the system is operating, the DAC960
 287driver queries each controller for status information every 10 seconds, and
 288checks for additional conditions every 60 seconds.  The initial status of each
 289controller is always available for controller N in /proc/rd/cN/initial_status,
 290and the current status as of the last status monitoring query is available in
 291/proc/rd/cN/current_status.  In addition, status changes are also logged by the
 292driver to the system console and will appear in the log files maintained by
 293syslog.  The progress of asynchronous rebuild or consistency check operations
 294is also available in /proc/rd/cN/current_status, and progress messages are
 295logged to the system console at most every 60 seconds.
 296
 297Starting with the 2.2.3/2.0.3 versions of the driver, the status information
 298available in /proc/rd/cN/initial_status and /proc/rd/cN/current_status has been
 299augmented to include the vendor, model, revision, and serial number (if
 300available) for each physical device found connected to the controller:
 301
 302***** DAC960 RAID Driver Version 2.2.3 of 19 August 1999 *****
 303Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
 304Configuring Mylex DAC960PRL PCI RAID Controller
 305  Firmware Version: 4.07-0-07, Channels: 1, Memory Size: 16MB
 306  PCI Bus: 1, Device: 4, Function: 1, I/O Address: Unassigned
 307  PCI Address: 0xFE300000 mapped at 0xA0800000, IRQ Channel: 21
 308  Controller Queue Depth: 128, Maximum Blocks per Command: 128
 309  Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
 310  Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
 311  SAF-TE Enclosure Management Enabled
 312  Physical Devices:
 313    0:0  Vendor: IBM       Model: DRVS09D           Revision: 0270
 314         Serial Number:       68016775HA
 315         Disk Status: Online, 17928192 blocks
 316    0:1  Vendor: IBM       Model: DRVS09D           Revision: 0270
 317         Serial Number:       68004E53HA
 318         Disk Status: Online, 17928192 blocks
 319    0:2  Vendor: IBM       Model: DRVS09D           Revision: 0270
 320         Serial Number:       13013935HA
 321         Disk Status: Online, 17928192 blocks
 322    0:3  Vendor: IBM       Model: DRVS09D           Revision: 0270
 323         Serial Number:       13016897HA
 324         Disk Status: Online, 17928192 blocks
 325    0:4  Vendor: IBM       Model: DRVS09D           Revision: 0270
 326         Serial Number:       68019905HA
 327         Disk Status: Online, 17928192 blocks
 328    0:5  Vendor: IBM       Model: DRVS09D           Revision: 0270
 329         Serial Number:       68012753HA
 330         Disk Status: Online, 17928192 blocks
 331    0:6  Vendor: ESG-SHV   Model: SCA HSBP M6       Revision: 0.61
 332  Logical Drives:
 333    /dev/rd/c0d0: RAID-5, Online, 89640960 blocks, Write Thru
 334  No Rebuild or Consistency Check in Progress
 335
 336To simplify the monitoring process for custom software, the special file
 337/proc/rd/status returns "OK" when all DAC960 controllers in the system are
 338operating normally and no failures have occurred, or "ALERT" if any logical
 339drives are offline or critical or any non-standby physical drives are dead.
 340
 341Configuration commands for controller N are available via the special file
 342/proc/rd/cN/user_command.  A human readable command can be written to this
 343special file to initiate a configuration operation, and the results of the
 344operation can then be read back from the special file in addition to being
 345logged to the system console.  The shell command sequence
 346
 347  echo "<configuration-command>" > /proc/rd/c0/user_command
 348  cat /proc/rd/c0/user_command
 349
 350is typically used to execute configuration commands.  The configuration
 351commands are:
 352
 353  flush-cache
 354
 355    The "flush-cache" command flushes the controller's cache.  The system
 356    automatically flushes the cache at shutdown or if the driver module is
 357    unloaded, so this command is only needed to be certain a write back cache
 358    is flushed to disk before the system is powered off by a command to a UPS.
 359    Note that the flush-cache command also stops an asynchronous rebuild or
 360    consistency check, so it should not be used except when the system is being
 361    halted.
 362
 363  kill <channel>:<target-id>
 364
 365    The "kill" command marks the physical drive <channel>:<target-id> as DEAD.
 366    This command is provided primarily for testing, and should not be used
 367    during normal system operation.
 368
 369  make-online <channel>:<target-id>
 370
 371    The "make-online" command changes the physical drive <channel>:<target-id>
 372    from status DEAD to status ONLINE.  In cases where multiple physical drives
 373    have been killed simultaneously, this command may be used to bring all but
 374    one of them back online, after which a rebuild to the final drive is
 375    necessary.
 376
 377    Warning: make-online should only be used on a dead physical drive that is
 378    an active part of a drive group, never on a standby drive.  The command
 379    should never be used on a dead drive that is part of a critical logical
 380    drive; rebuild should be used if only a single drive is dead.
 381
 382  make-standby <channel>:<target-id>
 383
 384    The "make-standby" command changes physical drive <channel>:<target-id>
 385    from status DEAD to status STANDBY.  It should only be used in cases where
 386    a dead drive was replaced after an automatic rebuild was performed onto a
 387    standby drive.  It cannot be used to add a standby drive to the controller
 388    configuration if one was not created initially; the BIOS Configuration
 389    Utility must be used for that currently.
 390
 391  rebuild <channel>:<target-id>
 392
 393    The "rebuild" command initiates an asynchronous rebuild onto physical drive
 394    <channel>:<target-id>.  It should only be used when a dead drive has been
 395    replaced.
 396
 397  check-consistency <logical-drive-number>
 398
 399    The "check-consistency" command initiates an asynchronous consistency check
 400    of <logical-drive-number> with automatic restoration.  It can be used
 401    whenever it is desired to verify the consistency of the redundancy
 402    information.
 403
 404  cancel-rebuild
 405  cancel-consistency-check
 406
 407    The "cancel-rebuild" and "cancel-consistency-check" commands cancel any
 408    rebuild or consistency check operations previously initiated.
 409
 410
 411               EXAMPLE I - DRIVE FAILURE WITHOUT A STANDBY DRIVE
 412
 413The following annotated logs demonstrate the controller configuration and and
 414online status monitoring capabilities of the Linux DAC960 Driver.  The test
 415configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a
 416DAC960PJ controller.  The physical drives are configured into a single drive
 417group without a standby drive, and the drive group has been configured into two
 418logical drives, one RAID-5 and one RAID-6.  Note that these logs are from an
 419earlier version of the driver and the messages have changed somewhat with newer
 420releases, but the functionality remains similar.  First, here is the current
 421status of the RAID configuration:
 422
 423gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 424***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
 425Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
 426Configuring Mylex DAC960PJ PCI RAID Controller
 427  Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
 428  PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
 429  PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
 430  Controller Queue Depth: 128, Maximum Blocks per Command: 128
 431  Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
 432  Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
 433  Physical Devices:
 434    0:1 - Disk: Online, 2201600 blocks
 435    0:2 - Disk: Online, 2201600 blocks
 436    0:3 - Disk: Online, 2201600 blocks
 437    1:1 - Disk: Online, 2201600 blocks
 438    1:2 - Disk: Online, 2201600 blocks
 439    1:3 - Disk: Online, 2201600 blocks
 440  Logical Drives:
 441    /dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru
 442    /dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru
 443  No Rebuild or Consistency Check in Progress
 444
 445gwynedd:/u/lnz# cat /proc/rd/status
 446OK
 447
 448The above messages indicate that everything is healthy, and /proc/rd/status
 449returns "OK" indicating that there are no problems with any DAC960 controller
 450in the system.  For demonstration purposes, while I/O is active Physical Drive
 4511:1 is now disconnected, simulating a drive failure.  The failure is noted by
 452the driver within 10 seconds of the controller's having detected it, and the
 453driver logs the following console status messages indicating that Logical
 454Drives 0 and 1 are now CRITICAL as a result of Physical Drive 1:1 being DEAD:
 455
 456DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
 457DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
 458DAC960#0: Physical Drive 1:1 killed because of timeout on SCSI command
 459DAC960#0: Physical Drive 1:1 is now DEAD
 460DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL
 461DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL
 462
 463The Sense Keys logged here are just Check Condition / Unit Attention conditions
 464arising from a SCSI bus reset that is forced by the controller during its error
 465recovery procedures.  Concurrently with the above, the driver status available
 466from /proc/rd also reflects the drive failure.  The status message in
 467/proc/rd/status has changed from "OK" to "ALERT":
 468
 469gwynedd:/u/lnz# cat /proc/rd/status
 470ALERT
 471
 472and /proc/rd/c0/current_status has been updated:
 473
 474gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 475  ...
 476  Physical Devices:
 477    0:1 - Disk: Online, 2201600 blocks
 478    0:2 - Disk: Online, 2201600 blocks
 479    0:3 - Disk: Online, 2201600 blocks
 480    1:1 - Disk: Dead, 2201600 blocks
 481    1:2 - Disk: Online, 2201600 blocks
 482    1:3 - Disk: Online, 2201600 blocks
 483  Logical Drives:
 484    /dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
 485    /dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
 486  No Rebuild or Consistency Check in Progress
 487
 488Since there are no standby drives configured, the system can continue to access
 489the logical drives in a performance degraded mode until the failed drive is
 490replaced and a rebuild operation completed to restore the redundancy of the
 491logical drives.  Once Physical Drive 1:1 is replaced with a properly
 492functioning drive, or if the physical drive was killed without having failed
 493(e.g., due to electrical problems on the SCSI bus), the user can instruct the
 494controller to initiate a rebuild operation onto the newly replaced drive:
 495
 496gwynedd:/u/lnz# echo "rebuild 1:1" > /proc/rd/c0/user_command
 497gwynedd:/u/lnz# cat /proc/rd/c0/user_command
 498Rebuild of Physical Drive 1:1 Initiated
 499
 500The echo command instructs the controller to initiate an asynchronous rebuild
 501operation onto Physical Drive 1:1, and the status message that results from the
 502operation is then available for reading from /proc/rd/c0/user_command, as well
 503as being logged to the console by the driver.
 504
 505Within 10 seconds of this command the driver logs the initiation of the
 506asynchronous rebuild operation:
 507
 508DAC960#0: Rebuild of Physical Drive 1:1 Initiated
 509DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01
 510DAC960#0: Physical Drive 1:1 is now WRITE-ONLY
 511DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 1% completed
 512
 513and /proc/rd/c0/current_status is updated:
 514
 515gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 516  ...
 517  Physical Devices:
 518    0:1 - Disk: Online, 2201600 blocks
 519    0:2 - Disk: Online, 2201600 blocks
 520    0:3 - Disk: Online, 2201600 blocks
 521    1:1 - Disk: Write-Only, 2201600 blocks
 522    1:2 - Disk: Online, 2201600 blocks
 523    1:3 - Disk: Online, 2201600 blocks
 524  Logical Drives:
 525    /dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
 526    /dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
 527  Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 6% completed
 528
 529As the rebuild progresses, the current status in /proc/rd/c0/current_status is
 530updated every 10 seconds:
 531
 532gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 533  ...
 534  Physical Devices:
 535    0:1 - Disk: Online, 2201600 blocks
 536    0:2 - Disk: Online, 2201600 blocks
 537    0:3 - Disk: Online, 2201600 blocks
 538    1:1 - Disk: Write-Only, 2201600 blocks
 539    1:2 - Disk: Online, 2201600 blocks
 540    1:3 - Disk: Online, 2201600 blocks
 541  Logical Drives:
 542    /dev/rd/c0d0: RAID-5, Critical, 5498880 blocks, Write Thru
 543    /dev/rd/c0d1: RAID-6, Critical, 3305472 blocks, Write Thru
 544  Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 15% completed
 545
 546and every minute a progress message is logged to the console by the driver:
 547
 548DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 32% completed
 549DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 63% completed
 550DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 94% completed
 551DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 94% completed
 552
 553Finally, the rebuild completes successfully.  The driver logs the status of the 
 554logical and physical drives and the rebuild completion:
 555
 556DAC960#0: Rebuild Completed Successfully
 557DAC960#0: Physical Drive 1:1 is now ONLINE
 558DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE
 559DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE
 560
 561/proc/rd/c0/current_status is updated:
 562
 563gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 564  ...
 565  Physical Devices:
 566    0:1 - Disk: Online, 2201600 blocks
 567    0:2 - Disk: Online, 2201600 blocks
 568    0:3 - Disk: Online, 2201600 blocks
 569    1:1 - Disk: Online, 2201600 blocks
 570    1:2 - Disk: Online, 2201600 blocks
 571    1:3 - Disk: Online, 2201600 blocks
 572  Logical Drives:
 573    /dev/rd/c0d0: RAID-5, Online, 5498880 blocks, Write Thru
 574    /dev/rd/c0d1: RAID-6, Online, 3305472 blocks, Write Thru
 575  Rebuild Completed Successfully
 576
 577and /proc/rd/status indicates that everything is healthy once again:
 578
 579gwynedd:/u/lnz# cat /proc/rd/status
 580OK
 581
 582
 583                EXAMPLE II - DRIVE FAILURE WITH A STANDBY DRIVE
 584
 585The following annotated logs demonstrate the controller configuration and and
 586online status monitoring capabilities of the Linux DAC960 Driver.  The test
 587configuration comprises 6 1GB Quantum Atlas I disk drives on two channels of a
 588DAC960PJ controller.  The physical drives are configured into a single drive
 589group with a standby drive, and the drive group has been configured into two
 590logical drives, one RAID-5 and one RAID-6.  Note that these logs are from an
 591earlier version of the driver and the messages have changed somewhat with newer
 592releases, but the functionality remains similar.  First, here is the current
 593status of the RAID configuration:
 594
 595gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 596***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
 597Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
 598Configuring Mylex DAC960PJ PCI RAID Controller
 599  Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
 600  PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
 601  PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
 602  Controller Queue Depth: 128, Maximum Blocks per Command: 128
 603  Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
 604  Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
 605  Physical Devices:
 606    0:1 - Disk: Online, 2201600 blocks
 607    0:2 - Disk: Online, 2201600 blocks
 608    0:3 - Disk: Online, 2201600 blocks
 609    1:1 - Disk: Online, 2201600 blocks
 610    1:2 - Disk: Online, 2201600 blocks
 611    1:3 - Disk: Standby, 2201600 blocks
 612  Logical Drives:
 613    /dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
 614    /dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
 615  No Rebuild or Consistency Check in Progress
 616
 617gwynedd:/u/lnz# cat /proc/rd/status
 618OK
 619
 620The above messages indicate that everything is healthy, and /proc/rd/status
 621returns "OK" indicating that there are no problems with any DAC960 controller
 622in the system.  For demonstration purposes, while I/O is active Physical Drive
 6231:2 is now disconnected, simulating a drive failure.  The failure is noted by
 624the driver within 10 seconds of the controller's having detected it, and the
 625driver logs the following console status messages:
 626
 627DAC960#0: Physical Drive 1:1 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
 628DAC960#0: Physical Drive 1:3 Error Log: Sense Key = 6, ASC = 29, ASCQ = 02
 629DAC960#0: Physical Drive 1:2 killed because of timeout on SCSI command
 630DAC960#0: Physical Drive 1:2 is now DEAD
 631DAC960#0: Physical Drive 1:2 killed because it was removed
 632DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now CRITICAL
 633DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now CRITICAL
 634
 635Since a standby drive is configured, the controller automatically begins
 636rebuilding onto the standby drive:
 637
 638DAC960#0: Physical Drive 1:3 is now WRITE-ONLY
 639DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed
 640
 641Concurrently with the above, the driver status available from /proc/rd also
 642reflects the drive failure and automatic rebuild.  The status message in
 643/proc/rd/status has changed from "OK" to "ALERT":
 644
 645gwynedd:/u/lnz# cat /proc/rd/status
 646ALERT
 647
 648and /proc/rd/c0/current_status has been updated:
 649
 650gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 651  ...
 652  Physical Devices:
 653    0:1 - Disk: Online, 2201600 blocks
 654    0:2 - Disk: Online, 2201600 blocks
 655    0:3 - Disk: Online, 2201600 blocks
 656    1:1 - Disk: Online, 2201600 blocks
 657    1:2 - Disk: Dead, 2201600 blocks
 658    1:3 - Disk: Write-Only, 2201600 blocks
 659  Logical Drives:
 660    /dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru
 661    /dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru
 662  Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 4% completed
 663
 664As the rebuild progresses, the current status in /proc/rd/c0/current_status is
 665updated every 10 seconds:
 666
 667gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 668  ...
 669  Physical Devices:
 670    0:1 - Disk: Online, 2201600 blocks
 671    0:2 - Disk: Online, 2201600 blocks
 672    0:3 - Disk: Online, 2201600 blocks
 673    1:1 - Disk: Online, 2201600 blocks
 674    1:2 - Disk: Dead, 2201600 blocks
 675    1:3 - Disk: Write-Only, 2201600 blocks
 676  Logical Drives:
 677    /dev/rd/c0d0: RAID-5, Critical, 4399104 blocks, Write Thru
 678    /dev/rd/c0d1: RAID-6, Critical, 2754560 blocks, Write Thru
 679  Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed
 680
 681and every minute a progress message is logged on the console by the driver:
 682
 683DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 40% completed
 684DAC960#0: Rebuild in Progress: Logical Drive 0 (/dev/rd/c0d0) 76% completed
 685DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 66% completed
 686DAC960#0: Rebuild in Progress: Logical Drive 1 (/dev/rd/c0d1) 84% completed
 687
 688Finally, the rebuild completes successfully.  The driver logs the status of the 
 689logical and physical drives and the rebuild completion:
 690
 691DAC960#0: Rebuild Completed Successfully
 692DAC960#0: Physical Drive 1:3 is now ONLINE
 693DAC960#0: Logical Drive 0 (/dev/rd/c0d0) is now ONLINE
 694DAC960#0: Logical Drive 1 (/dev/rd/c0d1) is now ONLINE
 695
 696/proc/rd/c0/current_status is updated:
 697
 698***** DAC960 RAID Driver Version 2.0.0 of 23 March 1999 *****
 699Copyright 1998-1999 by Leonard N. Zubkoff <lnz@dandelion.com>
 700Configuring Mylex DAC960PJ PCI RAID Controller
 701  Firmware Version: 4.06-0-08, Channels: 3, Memory Size: 8MB
 702  PCI Bus: 0, Device: 19, Function: 1, I/O Address: Unassigned
 703  PCI Address: 0xFD4FC000 mapped at 0x8807000, IRQ Channel: 9
 704  Controller Queue Depth: 128, Maximum Blocks per Command: 128
 705  Driver Queue Depth: 127, Maximum Scatter/Gather Segments: 33
 706  Stripe Size: 64KB, Segment Size: 8KB, BIOS Geometry: 255/63
 707  Physical Devices:
 708    0:1 - Disk: Online, 2201600 blocks
 709    0:2 - Disk: Online, 2201600 blocks
 710    0:3 - Disk: Online, 2201600 blocks
 711    1:1 - Disk: Online, 2201600 blocks
 712    1:2 - Disk: Dead, 2201600 blocks
 713    1:3 - Disk: Online, 2201600 blocks
 714  Logical Drives:
 715    /dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
 716    /dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru
 717  Rebuild Completed Successfully
 718
 719and /proc/rd/status indicates that everything is healthy once again:
 720
 721gwynedd:/u/lnz# cat /proc/rd/status
 722OK
 723
 724Note that the absence of a viable standby drive does not create an "ALERT"
 725status.  Once dead Physical Drive 1:2 has been replaced, the controller must be
 726told that this has occurred and that the newly replaced drive should become the
 727new standby drive:
 728
 729gwynedd:/u/lnz# echo "make-standby 1:2" > /proc/rd/c0/user_command
 730gwynedd:/u/lnz# cat /proc/rd/c0/user_command
 731Make Standby of Physical Drive 1:2 Succeeded
 732
 733The echo command instructs the controller to make Physical Drive 1:2 into a
 734standby drive, and the status message that results from the operation is then
 735available for reading from /proc/rd/c0/user_command, as well as being logged to
 736the console by the driver.  Within 60 seconds of this command the driver logs:
 737
 738DAC960#0: Physical Drive 1:2 Error Log: Sense Key = 6, ASC = 29, ASCQ = 01
 739DAC960#0: Physical Drive 1:2 is now STANDBY
 740DAC960#0: Make Standby of Physical Drive 1:2 Succeeded
 741
 742and /proc/rd/c0/current_status is updated:
 743
 744gwynedd:/u/lnz# cat /proc/rd/c0/current_status
 745  ...
 746  Physical Devices:
 747    0:1 - Disk: Online, 2201600 blocks
 748    0:2 - Disk: Online, 2201600 blocks
 749    0:3 - Disk: Online, 2201600 blocks
 750    1:1 - Disk: Online, 2201600 blocks
 751    1:2 - Disk: Standby, 2201600 blocks
 752    1:3 - Disk: Online, 2201600 blocks
 753  Logical Drives:
 754    /dev/rd/c0d0: RAID-5, Online, 4399104 blocks, Write Thru
 755    /dev/rd/c0d1: RAID-6, Online, 2754560 blocks, Write Thru