   2        (C) 2011 MyungJoo Ham <myungjoo.ham@samsung.com>, GPL
   3
   4Charger Manager provides in-kernel battery charger management that
   5requires temperature monitoring during suspend-to-RAM state
   6and where each battery may have multiple chargers attached and the userland
   7wants to look at the aggregated information of the multiple chargers.
   8
   9Charger Manager is a platform_driver with power-supply-class entries.
  10An instance of Charger Manager (a platform-device created with Charger-Manager)
  11represents an independent battery with chargers. If there are multiple
  12batteries with their own chargers acting independently in a system,
  13the system may need multiple instances of Charger Manager.
  14
  151. Introduction
  16===============
  17
  18Charger Manager supports the following:
  19
  20* Support for multiple chargers (e.g., a device with USB, AC, and solar panels)
  21        A system may have multiple chargers (or power sources) and some of
  22        they may be activated at the same time. Each charger may have its
  23        own power-supply-class and each power-supply-class can provide
  24        different information about the battery status. This framework
  25        aggregates charger-related information from multiple sources and
  26        shows combined information as a single power-supply-class.
  27
  28* Support for in suspend-to-RAM polling (with suspend_again callback)
  29        While the battery is being charged and the system is in suspend-to-RAM,
  30        we may need to monitor the battery health by looking at the ambient or
  31        battery temperature. We can accomplish this by waking up the system
  32        periodically. However, such a method wakes up devices unncessary for
  33        monitoring the battery health and tasks, and user processes that are
  34        supposed to be kept suspended. That, in turn, incurs unnecessary power
  35        consumption and slow down charging process. Or even, such peak power
  36        consumption can stop chargers in the middle of charging
  37        (external power input < device power consumption), which not
  38        only affects the charging time, but the lifespan of the battery.
  39
  40        Charger Manager provides a function "cm_suspend_again" that can be
  41        used as suspend_again callback of platform_suspend_ops. If the platform
  42        requires tasks other than cm_suspend_again, it may implement its own
  43        suspend_again callback that calls cm_suspend_again in the middle.
  44        Normally, the platform will need to resume and suspend some devices
  45        that are used by Charger Manager.
  46
  472. Global Charger-Manager Data related with suspend_again
  48========================================================
  49In order to setup Charger Manager with suspend-again feature
  50(in-suspend monitoring), the user should provide charger_global_desc
  51with setup_charger_manager(struct charger_global_desc *).
  52This charger_global_desc data for in-suspend monitoring is global
  53as the name suggests. Thus, the user needs to provide only once even
  54if there are multiple batteries. If there are multiple batteries, the
  55multiple instances of Charger Manager share the same charger_global_desc
  56and it will manage in-suspend monitoring for all instances of Charger Manager.
  57
  58The user needs to provide all the two entries properly in order to activate
  59in-suspend monitoring:
  60
  61struct charger_global_desc {
  62
  63char *rtc_name;
  64        : The name of rtc (e.g., "rtc0") used to wakeup the system from
  65        suspend for Charger Manager. The alarm interrupt (AIE) of the rtc
  66        should be able to wake up the system from suspend. Charger Manager
  67        saves and restores the alarm value and use the previously-defined
  68        alarm if it is going to go off earlier than Charger Manager so that
  69        Charger Manager does not interfere with previously-defined alarms.
  70
  71bool (*rtc_only_wakeup)(void);
  72        : This callback should let CM know whether
  73        the wakeup-from-suspend is caused only by the alarm of "rtc" in the
  74        same struct. If there is any other wakeup source triggered the
  75        wakeup, it should return false. If the "rtc" is the only wakeup
  76        reason, it should return true.
  77};
  78
  793. How to setup suspend_again
  80=============================
  81Charger Manager provides a function "extern bool cm_suspend_again(void)".
  82When cm_suspend_again is called, it monitors every battery. The suspend_ops
  83callback of the system's platform_suspend_ops can call cm_suspend_again
  84function to know whether Charger Manager wants to suspend again or not.
  85If there are no other devices or tasks that want to use suspend_again
  86feature, the platform_suspend_ops may directly refer to cm_suspend_again
  87for its suspend_again callback.
  88
  89The cm_suspend_again() returns true (meaning "I want to suspend again")
  90if the system was woken up by Charger Manager and the polling
  91(in-suspend monitoring) results in "normal".
  92
  934. Charger-Manager Data (struct charger_desc)
  94=============================================
  95For each battery charged independently from other batteries (if a series of
  96batteries are charged by a single charger, they are counted as one independent
  97battery), an instance of Charger Manager is attached to it.
  98
  99struct charger_desc {
 100
 101char *psy_name;
 102        : The power-supply-class name of the battery. Default is
 103        "battery" if psy_name is NULL. Users can access the psy entries
 104        at "/sys/class/power_supply/[psy_name]/".
 105
 106enum polling_modes polling_mode;
 107        : CM_POLL_DISABLE: do not poll this battery.
 108          CM_POLL_ALWAYS: always poll this battery.
 109          CM_POLL_EXTERNAL_POWER_ONLY: poll this battery if and only if
 110                                       an external power source is attached.
 111          CM_POLL_CHARGING_ONLY: poll this battery if and only if the
 112                                 battery is being charged.
 113
 114unsigned int fullbatt_uV;
 115        : If specified with a non-zero value, Charger Manager assumes
 116        that the battery is full (capacity = 100) if the battery is not being
 117        charged and the battery voltage is equal to or greater than
 118        fullbatt_uV.
 119
 120unsigned int polling_interval_ms;
 121        : Required polling interval in ms. Charger Manager will poll
 122        this battery every polling_interval_ms or more frequently.
 123
 124enum data_source battery_present;
 125        CM_FUEL_GAUGE: get battery presence information from fuel gauge.
 126        CM_CHARGER_STAT: get battery presence from chargers.
 127
 128char **psy_charger_stat;
 129        : An array ending with NULL that has power-supply-class names of
 130        chargers. Each power-supply-class should provide "PRESENT" (if
 131        battery_present is "CM_CHARGER_STAT"), "ONLINE" (shows whether an
 132        external power source is attached or not), and "STATUS" (shows whether
 133        the battery is {"FULL" or not FULL} or {"FULL", "Charging",
 134        "Discharging", "NotCharging"}).
 135
 136int num_charger_regulators;
 137struct regulator_bulk_data *charger_regulators;
 138        : Regulators representing the chargers in the form for
 139        regulator framework's bulk functions.
 140
 141char *psy_fuel_gauge;
 142        : Power-supply-class name of the fuel gauge.
 143
 144int (*temperature_out_of_range)(int *mC);
 145bool measure_battery_temp;
 146        : This callback returns 0 if the temperature is safe for charging,
 147        a positive number if it is too hot to charge, and a negative number
 148        if it is too cold to charge. With the variable mC, the callback returns
 149        the temperature in 1/1000 of centigrade.
 150        The source of temperature can be battery or ambient one according to
 151        the value of measure_battery_temp.
 152};
 153
 1545. Other Considerations
 155=======================
 156
 157At the charger/battery-related events such as battery-pulled-out,
 158charger-pulled-out, charger-inserted, DCIN-over/under-voltage, charger-stopped,
 159and others critical to chargers, the system should be configured to wake up.
 160At least the following should wake up the system from a suspend:
 161a) charger-on/off b) external-power-in/out c) battery-in/out (while charging)
 162